Daily maintenance of Multi-angle gloss meter

News

Check category

Hot Products

Daily maintenance of Multi-angle gloss meter

  • Time of issue:2022-04-27

(Summary description)Strong light should be avoided in the use of Multi-angle gloss meter

Daily maintenance of Multi-angle gloss meter

(Summary description)Strong light should be avoided in the use of Multi-angle gloss meter

Information

1. Strong light should be avoided in the use of Multi-angle gloss meter

Multi-angle gloss meter

2. The instrument is equipped with two standard boards. It should be kept clean, and it is not advisable to touch the surface with fingers. If the surface is stained, the error of the instrument will increase and the reading will be inaccurate. If you accidentally touch it, you can wipe it with lens tissue or anhydrous alcohol.

3. Due to the high stability of the instrument, the instrument does not need to be calibrated frequently. It is recommended to re-calibrate after 2 hours of continuous use.

4. The design of this instrument has a very high battery usage rate. When the battery is used below 0.8V (battery power is exhausted), the instrument reading begins to decline, and the red light-emitting diode in the upper right corner of the instrument displays, indicating that the operator needs to replace the battery. Turn on the left side of the instrument. The instrument can be reused after removing the side battery compartment cover. The battery should be replaced in time when it is exhausted. Otherwise, if the old battery is stored for a long time, the old battery may flow out of waste liquid and cause damage to the instrument.

5. During the calibration process, if it is found that the calibration value of the black glass standard class cannot be reached by rotating the calibration knob to the end, it may be that the optical lens of the instrument is seriously polluted. Wipe the lens with lens paper and a little anhydrous alcohol to solve the problem. question.

First, use a calibration plate with a known gloss value for calibration, set the gloss value of this calibration plate, and the light intensity emitted by the light source is the light intensity detected by the photocell. Through the calibration process, the light intensity of the light source can be known. The purpose of calibration is to eliminate the influence of changes in the intensity of the light source and environmental changes each time it is turned on. This step of calibration is very important. If the calibration is not done well, the measurement will be greatly affected. Therefore, in the calibration process, we must ensure that the bottom surface of the Multi-angle gloss meter and the calibration plate are in very close contact, and we also ensure the processing accuracy of the gloss bottom surface in the research and development.

Keyword:

Scan the QR code to read on your phone

Customer service
Customer service hotline
0086-595-22391041
Service time:
9:30 - 17:30
 KSJ

After eighteen-years’development, KSJ Glossmeters have been widely used all over the world in gloss measuring of paintwork, decorative  materials,  woodenwares,  ceramic,  printing ink, paper, as well as metal polishing and depositing.  And becoming the first choice for experts in the above fields.

Online Message

Username used for comment:
Client messages
Description:
验证码

Contact Us

264 Huangling, Zhangban Town, Taiwanese Investment Zone, Quanzhou,Fujian